3 hours ago Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    Click here to ask your question

What should the pressure be on a 4.5 worcester boiler and where is the pipe?

I need to know where the pipe is to top up the pressure and what the pressure gauge should read Help Elizabeth
Elizabeth Linford, March 2012
Take a look on around the boiler,

you are looking for a silver braided hose,it maybe already connected to the system or it maybe somewhere near or ontop of the boiler.

one end is connected to the mains water pipe,the other end connected to the central heating system.

Its known as a fill loop.


If the fill loop is already connected,then open the valve on the central heating side first,then slowly open the valve on the mains side and fill to a pressure of 1.5 bar.

Close both valves,fire the boiler up and bleed the air out of the radiators.

paul, March 2012
where do you top up the pressure gauge on a 4.5 worcester boiler and what should the gauge read
Thanks

Elizabeth Linford, March 2012