Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Click here to ask your question

How can I fill my Vaillant 824E turbomax with water?

One of the rads was cold so I undid the bleed valve but not realising I have drained the boiler which I did not know at the time was not self filling. Now I cannot see how to fill it up.
ron, October 2006
Under the boiler to the right hand side there should be a small charging key. if not as you look up at the underside you will see two small silver boxes,with large flat blade screws open both of them and the boiler will start to fill. Charge to 1.0 / 1.5 Bar when cold when filled return both screws to the first position.

David, October 2006
link Click here to see other fixes for Vaillant 824E.