andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

vokera boiler problem?

compact 24 central heating pressure gauge rises when domestic hot tap open + water flow from overflow when i open a rad to drop pressure to 1 bar then close pressure rises to 3 bar again
richard, May 2012
vokera compact 24
GCN 47-094-??
pressure keeps rising & leaks from PRV overflow?
first of all make sure your filling loop valves are closed fully
take filling pipe off & check for drips from valves
with filling pipe removed if pressure still rises chances are the pipe in pipe heat exchanger is pinholed & needs replacing
test for pinholed heat exchanger by turning OFF cold water inlet to boiler
if pressure stabilizes then heatex definitely pinholed

manwithnoname, May 2012
When are you doing what.
ARE you setting to 1 bar, WHEN the system is cold? Pressure will always rise. Set to 1 bar when cold, should not reach 3 bar, unless a blockage somewhere, check valves etc on boiler

SD, May 2012
link Click here to see other fixes for Vokera Compact 24.