GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

baxi 105e still problems after new PCB installed?

replaced PCB. boiler will now try to fire up when central heating is selected with constant selected on the timer. but flame still dies after a couple of seconds, does this maybe 3 times then the neon for the flame failure starts flashing.

please HELP!!!

cheers Dave
dave taylor, October 2006
sorry,seems to be a regular feature of this boiler,i have 2 non working ones in a box.
the fault finding section in the manual always seems to say(replace pcb).
THE WORST AND MOST UNRELIABLE BOILER that i have ever used.
dogsy.

dogsy, September 2010
You might find that the problem is no more than a diaphragm failure.
There are 2 diaphragms one in the divertor valve(rear) and one in the dhw pressure dif valve(front).
I had a similar problem last year and found it to be the diaphragm.
Simple job and about a fiver for a new one.
Check that both pushrods are engaging the microswitches when calling for water or just the rear one if CH - if not the diaphragm has failed.
Or you might find it will engage initially then drop back due to lack of pressure and this will cause the flame to go out.

Brian, November 2006
Apologies for the rather obvious answer. You could contact Baxi and they should be able to help you I don't have the number here, (I got the number from my gas supplier) but they helped me a month or two back. I would reckon the engineer that diagnosed & replaced the PCB also should have an answer.

Chris, October 2006