Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

baxi solo 2 boiler keeps going out?

the pilot light is fine but when the burner kicks in the pilot will go out after a few seconds,this is intermittent sometimes it will stay on but more often than not it will go out.If you look through the veiwer you can see the pilot slowly going out from the back of it to the tip as if the gas is stopping.
walto, October 2006
thanks craig,but i cant see any pipes at the back of the boiler.it is a baxi solo 2 50

walto, October 2006
check the tubes underneath to the back right of the boiler that connect to the air pressure switch - sounds like they are either split or got a hole in them. you may be able to cut a bit off and just stick them back on.

craig, plymouth, October 2006