Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

Boiler has intermittent fault with firing up?

Have baxi solo 3 pfl 40 gas boiler. It powers up fine inthe morning but after a while it goes off. Boiler light on also fan but not pilot or burner. Have to switch the whole system off for about an hour then switch it on again and it powers up. Have new room stat and pump, both of which are working OK and pump continues to pump water even when it cools down.
Jean Stone, October 2012
Change air pressure switch

ltd, October 2012
link Click here to see other fixes for Baxi Solo 3.