Did a search for "Worcester Bosch 37cdi fault indication"
Found an instruciton manual and a servicing guide. See
http://www.acwilgar.co.uk/user-manual-for-greenstar-cdi.pdf
and
http://www.theplumbstore.com/downloads/dl/file/id/1331/installation_and_servicing_instructions_for_greenstar_cdi_part_1_of_2.pdf
plus
http://www.theplumbstore.com/downloads/dl/file/id/1332/installation_and_servicing_instructions_for_greenstar_cdi_part_2_of_2.pdf
Read the first PDF (http://www.acwilgar.co.uk/user-manual-for-greenstar-cdi.pdf) and you will see, on page 13:
• The boiler runs for 15 minutes at minimum heating output to fill the condensate trap, the display alternates between “-II-” and the central heating flow temperature. This occurs every time the mains supply has been interrupted.
Switch on, leave for at least 15 minutes and see if the teperature comes up to normal after the safety cycle has completed.
Anon, November 2012