GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Replace bath tap inner valve, combi boiler? Worcester heatslave 12/14?

Hi, I want to replace a loose tap inner valve, Can I turn off main water supply to house with a combi boiler? Then run off hot water the same way as with the older type of water system?
Once I have replaced the tap valve just turn boiler and water back on? Or do I need to re- pressure combi tank back up or any other complicated procedures?
I dont want to damage the combi in any way and I have no experience with combi boilers. Its a Worcester heatslave 12/14, approx 7 years old.
Any advise would be greatly appreciated.
Thanks.
Will, November 2012
Thanks Kash very much appreciated :)
All the best.

Will, November 2012
yes thats fine just turn off the mains supply it wil stop the cold into the boiler then no hot water produced. just drain the tap fix it the reopen the mains and everything will be good. you dont need to repressurise as thats only for central heating

kash, November 2012