Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

Boiler goes out after 15 Minutes?

Potterton RS50s flame goes out after 15 minutes.

New Thermocouple fitted, still problem
Graham R, December 2012
check the overheat stat as this also cuts of the gas valve. check also the thermostat on the boiler as it should cut the boiler off at certain temp. if its faulty the boiler will carry on heating causing the safety overheat to cut off the boiler. so it will be one or the other. hope this helps

kash, December 2012