GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

pilot lights but main burners dont?

glow worm bolier central heating and hot water
pete, November 2006
Sounds like the solenoid on your gas valve may have failed.Check that the power is all on to the boiler(sounds obvious but there may be the odd hidden switch that's been turned off by mistake).Also could be the boiler thermostat.If you are capable and have the correct test gear you can check for power at the solenoid on the gas valve.
If it is the gas valve then a corgi reg engineer will need to change this for you.
Hope this helps.
Pete 100%Heating

Pete Brown, November 2006