David asked ... Not starting until I bang door closed?    |    Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Click here to ask your question

My sabre 29he boiler is cutting in and out every 8 to 10 seconds?

I have a sabre 29he boiler its going thru the start up process with flame and fan then it cuts out the red light comes on. It then goes off and turns to green re ignites then cuts out again it does this on DHW and CH help

Think it's the PCB but there are 2

Any help would be appreciated
Clive, January 2013
check the flame electrode sensor. clean it with sand paper or replace it as this tells the boiler that a flame has been picked up if its faulty the boiler will keep trying to reignite. this is a common fault so first try this and if unsuccessful repost

kash, January 2013