Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Baxi 105e combi boiler - fan problem?

I have a 9 year old Baxi 105e combi, which has been regularly seviced and has had a hot water diaphragm replaced 2 years ago. Just recently the boiler has been failing after about 20 to 30 minutes, with the flashing red 'fan' symbol showing. No heating but the pump is still running, and no hot water. It works again after the next timed cycle, but again stops after a short period. My local gas fitter has replaced the PCB (twice) and has tested the fan but is now stuck. Any advice would be much appreciated.
Ray, November 2013
Spot on, air pressure switch replaced, everything now OK. Thanks

Ray, November 2013
Has the air pressure switch been checked?
The Venturi which is fitted to the fan is also a possible cause.

Baxi Eng, November 2013