Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

2amp fuse keeps blowing?

britony combi se80 boiler replaced the water pressure switch
which was leaking onto the pump now every time i replace the fuse it just blows all the lights come on for couple of seconds
before it blows could it be the pump
dave d, November 2013
disconnect the pump wiring then fit fuse.if it doesn't blow then yes it could be the pump but this test isn't a fool proof test.testing the pump with a meter is

A1, November 2013
its not rocket science mate water and electricity don't mix,so logic dictates if water go in the the pump then its going to blow the fuse,and by the way ,it should be 3 amp fuse ,you need to megger the pump for low insulation

mm, November 2013