GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Stupid Question Probably?

My boiler has locked out due to what seems to be low pressure (0) so I thought I would simply increase the pressure, but its not so easy as after having read the user manual I can't work out how to increase the pressure - any suggestions from someone who knows their worcesters from their walnuts?
kirk, December 2013
If looks like it is from the cold mains and joins up to the heating system then try it

toptrish, December 2013
Hi and thanks so much for your advice,

I have had a good ook and the only 'hoop' that fits your description - joining two pipes is only fitted bit a small blue lever that turns to a downward position - is this what I should turn?

Many thanks

Kirk

kirk, December 2013
There will be a filling loop usually close to the boiler it is a chrome plated flexible pipe about 300m long that "loops" from one pipe to another close by,it is usually already connected to the 2 pipes,there is a black tap on each end turn both on until pressure rises to 1.5 bar. turn both off when pressure achieved,job done

toptrish, December 2013