Alan asked ... Waring Blendor DL 202 Armature removal?    |    Anne asked ... Leaking Hotpoint Aquarius+ washer/dryer?    |    David asked ... Ignis adl347?    |    TJ asked ... Shredder won't turn off in between shredding documents?    |    Dir asked ... Melcom ST4500 Jaytech?    |    Click here to ask your question

vaillant vcw gb 282gh?

works ok for centralheating won't fire up for hot water, all fuses ok reset button in. thinking maybe something to do with diverter valve switch
bike man, May 2015
Most likely a worn diaphragm in the water valve.

To test the electrics side, there is a servo valve to the right of the electrical box, above the water valve. On the back of the valve there is an armature, push this down, if the boiler fires up, it confirms the diaphragm is worn and needs replacing.

Helper, May 2015