David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

Ariston Error Code E02 now A77?

Boiler loses pressure frequently, especially when cold, E02 code keeps coming up. After repressurising the boiler it works for a while before pressure drops again, from 1.1 (ish) bar to 0.5 Have checked the overflow for leaks and the central heating pipe work. No sign of any leaks but the water is going somewhere, now boiler is saying A77 code Condensing trap full, are these two separate faults? any ideas?
CJ, February 2016
E02: Condensate comes from the burner/flue area. Could a leaking heat exchanger (or closely associated pipework) also put water into the burner area?

A77: Could the condensate drain now be blocked with crud?

More stuff:

http://www.diynot.com/diy/threads/repressurised-pv-on-ariston-boiler-no-heating-or-water.350215/

And one oddball cause

http://fixfault.com/answers.php?id=1741

XXX, February 2016