Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Click here to ask your question

Worcester Greenstar 24Ri seems to have no power?

My Worcester Greenstar 24Ri boiler was working yesterday morning, but did not come on yesterday evening.

It is like is has no power. I'm sure the boiler is getting power. The programmer is fed from the same power source and it is working.

I've taken the housing off and checked fuse F1. This had blown. I replaced it and it has blown again.

What is likely to be wrong?
Ben, March 2017
Had a man come round and look at it. The transformer had gone.

Ben, March 2017
Get someone competent to look at it.

It HAS got power. The problem is there is a fault that is causing the fuse to blow.

My guess would be the main PCB but you need someone competent to look at it.

acp, March 2017