Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

How to fix a leak between the burner and heat exchanger?

A problem has been identified by an engineer on my 10 year old Isar HE30. It had a L F fault code which could not be reset. When the engineer removed the front cover he explained that condensate was leaking from the gasket between the burner and the heat exchanger. He said that this was dangerous as gases would be leaking out as well. He condemmed the boiler and capped of the gas supply. He left without anypossible remedial work apart from a new boiler. Was his diagnosis correct or was he just "pulling my chain"
Alan Young, December 2017
If the gasket is defective then surely the gasket only needs replacing doesn't it?

If it's the burner or the heat exchanger that are defective then they need replacing

?, May 2018