Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

combi boiler wont kick in?

i have a glowworm swift flow boiler
pilot comes on and stays on then when i go to turn on hot water tap or heating it goes out with no heat/hot water pressures fine and stays the same
can anyone help
cheers
rob harman, January 2007
Possibly 1 of three things; but difficult to say without seeing it...

If the pilot extinguish's the minute the main burner comes on; I would say you need a new pilot assembly, or at least the pilot deflector adjusted back onto the position.

If the burner fires for a couple of seconds, then it could just be your overheat thermostat is on its last legs and needs replacing, as it heats up; it breaks the connection and pops out the pilot.

If the burner ignites for a good 30 odd seconds and you get a little bit of a banging noise, I would suggest that possibly your pump has seized.

GasAid.co.uk, January 2007