Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Click here to ask your question

How do I top up pressure on a Vokera Excell 80 SP?

I have a Vokera Excell 80 SP and the pilot light has gone out and the pressure has dropped to less than 0.5 bar.
Is this stopping the pilot light from re-igniting?
How do I increase the pressure on the system, I've had a look in the user manual and it doesn't explain it.
Any help greatly appreciated, house is getting colder, missus moaning, kids crying, goldfish freezing etc etc

Cheers
Rob
Rob Manock, January 2007
The water comes from the cold water supply, there should be two taps from this supply on the bottom right of the boiler, one for the domestic hot water on a vertical pipe, the other on a horizontal pipe goes to a flexible pipe that goes left (the filling line) and fills the sealed system.
The pilot is probably going out due to suffocation; the fan is meant to run slowly when only the pilot is lit to supply air to the flame. A sticky fan bearing, an open 560 Ohm slow run wirewound resistor, a dry joint on that resistor, a dodgy (intermittent/broken) boiler pump flow sense microswitch, a sticky boiler pump flow microstick actuating rod etc could all cause this problem. Read the manual, or get a Vokera approved man (not any old corgi but someone who knows the model well) to service it. the boiler has a few quirks (flue venturi cleaning , DHW flow diaphrams) that need regular attention, but these are cheap and come as part of a proper service. The microswitches don't seem too reliable. There are mains voltages inside, be careful; failure to reassemble correctly could result in a carbon monoxide leak.

cd, January 2007
there should be a filling loop located near the boiler
but this should not stop you lighting the boiler. turn the boiler of at the power supply and try light the boiler without the fan runing if it lights sounds like the boiler is due a service

s.c, January 2007