Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Glow worm fuelsaver MK II Pilot light wont stay on?

My central heating boiler has started to play up, the pilot light keeps going out after about 15 miniutes, some times it stays on all day when I over ride it, but then lately it has become tempermental, working as I said above can anyone offer any advice please, I am retire now and on limited income so dont want to be spending money I dont need to, but its cold.
Mike, February 2007
Hi Mike
I agree with Pete, changing the thermocouple is cheap and sounds likely to solve the problem.
If you have loud bumping and banging noises coming from the boiler though I Have the same boiler and was told that the boiler should have a permanent mains supply and the pump should be wired up as per the diagram in-side the gold pull off cover. This is to allow the boiler to run the pump after the heating demand has stopped to cool the heat exchanger.

Martin, March 2008
Has anyone got a user manual for this type of water heater?

Ernie, February 2007
Try fitting a new thermocouple, not an expensive item

Pete, February 2007