GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

my baxi solo 2 has stopped working?

the boiler is not starting when asked to start the boiler on led lights and then there is a clicking noice in the control panel and the fanlight flashes breifly and nothing happens it then contiues with this cycle could the pcb be faulty or is it the fan
Michael cooper, April 2007
chaged the pcb and this cured the problem thanks for your help

mike, April 2007
All 3 lights on the control unit should be lit. If the right hand led is out, this typically indicates that the fan/pressure switch are not operating correctly. Try removing the silcon pipes from the pressure switch and blowing them through in case of water/condensation ingress

Neil D, April 2007
thanks mark tried that and the fan does not run at all just clicking noise on pcb

michael, April 2007
IF you turn the gas off and remove the casing you can then start the boiler and check if the fan runs..if it does run then possibly you have an air pressure switch fault or air pick up fault.(eg fan venturi dirty broken pressure switch tube)

mark, April 2007