Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Worcester 9.24 electronic Boiler H/water prob?

Hi

The central heating works fine but recently the burner would go off a few minutes after turning on the hot water and now switching on hot water taps does not ignite the boiler and obviously the water is cold.

I have been told that this may be the diverter valve, if so is this reasonably easy to fit and are they easy to get hold of?

Is there anything else it could be?

Many thanks for any help
David Brough, April 2007
If it is the diverter valve you can tell by watching the spindle on the top of the valve when you open the hot tap.It should lift far enough to operate the micro switches.If it doesnt, then the diaphram in the valve (below the switches)is the common culprit.Its a pig to do whether its the valve or the diaphram

John Warner, April 2007
link Click here to see other fixes for Worcester.