Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

baxi combi 80E co?

why does my safety thermostat cut out ???
rob, May 2007
The hot water microswitch on the diverter valve may be faulty keeping the boiler on. Put the selector switch on hot water only and if the boiler fires up with no hot water taps running replace the microswitch. The diverter and microswitch is at the bottom left hand side behind the control panel.

Ian., May 2007
You may be running the system too high. How often does it cut off? It could be several things. Poor circulation, partial blockage in a heat exchanger, burner pressure too high. Does it do it more on heating or hot water or same on both? How long has it been happening?

T.h.s, May 2007