Dir asked ... Melcom ST4500 Jaytech?    |    L Markle asked ... Heat resistant glue?    |    r bryant asked ... Radio will not play?    |    Eed asked ... Brother KR850?    |    Lynne asked ... Disable Alarm Scantronic 9800?    |    Click here to ask your question

Low flow on Mains Medway water heater?

I have tried descaling the pipe work of the heat exchanger, and when connected to a hose the flow rate seems fine. However, when back together the flow is very slow, and the gas jets don't really get going. The mains water pressure is low, but not that bad. However it has got worse over the last few years. Is there an adjustment that can be made? Is there anything other than heat exchanger that can get clogged up. Thanks for any advice. Main Medway, serial no. 55-54.
John Hill., May 2007
diapham in bottom water way split or venturi on water way clogged

steve b&h heating, May 2007