Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

Pilot Light keeps extinguishing?

Recently moved into a new house and we have a Potterton combi boiler (not sure on age but I would say fairly new). Since we have moved in the Pilot light has been extinguishing usually when the heating kicks in but now it is going out as soon as you turn on the hot water. Any suggestions please?
Hendo, June 2007
it still sounds like either a short pilot or a seal problem

gary.wright53@googlemail.com, June 2007
Yeah it lights fine. When the heating or hot water is turned on it kicks in then blows out shortly after.

Hendo, June 2007
does it light ok when you try, if so it could be either a blocked pilot injector, a dirty top socket(the bit the pilot flame comes out of), of the case not sealing correctly, also check the flue has not got any plants blocking it.

gary.wright53@googlemail.com, June 2007
link Click here to see other fixes for Potterton Combi boiler.