3 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

sime super 90 how to get hot water with out the rads been on?

if i have got the rads on the hot water is fine as soon as you turn the rads off the hot water goes cold it does not fire up put the rads back on its ok
geoff, February 2005
the same thing happens to mine i have had it replaced twice in twelve years its some rubber gasket that eventually breaks up my repair was only bout 60quid both times

gary reilly, February 2008
sounds like the diaphrams gone within the divert valve, you can buy a repair kit or just replace the whole thing.
you ckould also look to see if the pin on the diverter valve comes up high enough to reach the micro switches (big brass thing)

Ryan, February 2005
link Click here to see other fixes for Sime Super 90.