1 hour ago marc asked ... La machine 1 type 813?    |    Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    Click here to ask your question

glowworm ultimate 40ff?

i put the boiler on and the pilot lights but the main gas burner wont light up,the ignition just keeps sparking,i have replaced the pcb but it is still happening.
v reed, June 2007
I had this same problem, eventually found that it was sparking on the case as mentioned. I used insulating tape like others, but will now look at replacing with a more sturdy fix. Thanks

MJD1066, November 2008
Got the same problem with my ultimate, its sparking but not firing up, I have looked and realised that its actualy sparking onto the casing and the wire is slightlty charred, insualting tape works for a while but a new lead is required.

Tony m, January 2008
A common problem on the ultimate is the ignition lead shorting out on the casing where it enters the combustion chamber, I find that insulating the lead with silicone tubing cures this problem.
I have found them insulated with electrical tape, this works fine for a while but the heat causes it to break down.

gary.wright53@googlemail.com, July 2007
it is either a choked pilot or the electrode is faulty the message is not getting back to the pcb to go to the second stage this is a job for a competent corgi registered engineer

ricky, July 2007
If you do find out, please let me know!

Andy, June 2007