3 hours ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

c/heat blr netaheat mk2 10/16 not heating radiators?

my mother has a c/heat blr netaheat mk2 10/16 which heats up the water but has stopped heating the radiators. I presume the CH pump has failed. Is this the only possibility and is the pump built into the boiler and is it easy to change?
a harvey, July 2007
>I presume the CH pump has failed.

no, i would say your system is fully pumped. so if your pump had failed you wouldn't have water either.

> is the pump built into the boiler

no, most times your pump will be next to the copper cylinder in the airing cupboard

>Is this the only possibility


no

check your wall stat is clicking when turned up
if so then go to the airing cupboard and locate the copper cylinder your pump should be located next to that, and next to the will be a valve or maybe two depending if it's a y / s plan system
on the side of the valve is a lever in a slot push the lever across, it will have tension and slot the lever into the end groove. the boiler should fire up.

hi-spec plumbing, July 2007
link Click here to see other fixes for Netaheat MK2 10/16.