GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Emergency shutoff won't reset on Glow-worm Betacom 30?

The emergency shutoff light on my Glowworm Betacom 30 combi boiler has come on and will not allow me to reset the boiler. The instructions recommend switching the boiler off for a minute by tuning the dial to the off position, but the emergency light stays on, and the burner still fails to ignite. Switching it off at the mains also doesn't work. I can hear it trying to switch on (the click) but nothing happens - no hot water, no heating. The gas supply seems fine (the cooker works) and there is nothing obviously wrong on the external pipe at the side of the house. Help.
Tanya, July 2007
Pressure up to 1.5 and it came on immediately

Dave, January 2013
Thanks a lot for that i was going to call Glow worm to book an engineer but it worked. Once again Thanks

Mick, March 2010
Im a qualified plumber but not a boiler engineer. Ive just woken up to find exactly the same problem. I have always run my boiler around 1.0 - 1.3 bar without any problems (boiler is nearly 3yrs old) but all of a sudden it doesnt like it. Possibly a faulty pressure switch but hey this remedy works just fine...thanks so much, this has saved me the £200 call out charge by Glow Worm just to open a valve!!

Lee, February 2010
i have the same problem but dont know how to change the pressure?

Kelly, January 2009
Just had this problem myself, very good advice! worked for me too... Thanks

Paul., January 2009
thanks, the boiler fired up straight away when you put the pressure up to 1.5 bar.

gavin, December 2007
I had the same problem and this worked for me.

Thanks Garry

Chris, December 2007
Make sure pressure is up to 1.5 bar or it will not kick in try that

Garry, December 2007