Hi, I have a sime 80e and had the same problem, you are right to check out the pressure switch, this is done by testing the 240 volt supply on the control box pcb teminals 5,6,7, with your meter -lead on terminal 1 [N],but if you have proved the pressure switch is operating then the problem is definitly on the pcb,to sort this out you have two ways 1 buy a new control pcb at £72.00 minimum inc vat or 2 [ and this is what i have done], remove the pcb, the one fitted to the gas valve, and with an eye glass ie 10x magnification look at every soldered joint and you will find the joints to do with the relays that open the gas valves are cracked around the pyramid of
solder [a dry joint] check all joints I found about 12 very fine cracks,after resolering and fitting the pcb back, the boiler is now as new,by the way it has taken me 2 years to sort this out but was told every time to replace this pcb ,i mend boiler so i was not prepared to buy a new pcb knowing once i proved
it was the pcb i could repair it.if you need any more details then email me on r.roberts97@ntlworld.com take care ie be safe when working on gas or elect let me know how you have
gone on [its not hard to do this job if you can use a soldering iron] i will give you all the help i can .keep smiling bob roberts.
bob roberts, February 2006