katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Click here to ask your question

Glowworm Ultimate 40FF - main burner keeps going out and relighting?

The pilot lights, its continues to spark then the main burner lights then the main burner goes out after a few seconds but the pilot stays lit then the main burner relights again and the cycle continues over and over. This happens whether its trying to heat the hot water, central heating or both. So far, a corgi engineer has replaced the air pressure switch, pilot assembly, fan, gas valve and PCB but the problem continues. What else could it be?
Clare, September 2007
air venture blocked

and, January 2008
not worked on the 40 ff but it it could be the flame rectification lead or probe that require attention

alan, September 2007
air pressure switch, pilot assembly, fan has done its job if pilot is alight must be pcb or gas valve. asol check eletric polarity

kris, September 2007