Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Baxi 105E Combi boiler?

We have a Baxi 105E Combi boiler - only around 2 years old. The hot water will not reach temp and stays luke warm at best. If the hot water is turned on when the central heating is running the burner turns off. Any help would be appreciated.
Crb, November 2007
Probably Hot water sensor needs replacing. Quite a simple job, your boiler instructions will tell you where it is (on the side of the diverter valve).

You need to turn off cold supply to boiler and open hot taps to drain. Turn off electricity, undo wire from sensor (lift small clip on side and pull off) then use a 13mm spanner to undo sensor replace ensure fibre washer is in place

PJ, November 2007