Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

how can i fix my glowworm swiftfow 80?

every time i turn the heating on, it starts up fine but only runs for about 10 min`s then goes out but the pilot goes out too? i spent the other night re-lighting the boiler every 15 min`s because of this (and it was too cold not to!). the hot water works fine, it`s just the central heating. the fan was recently replaced and all worked well up till this week ??
jon connolly, November 2007
either the fan hasnt been fitted correctly or you have a worn thermocouple or blocked pilot. If the combustion case isnt fitted correctly (esp on bottom r/h side) this can cause the pilot to lift away from the thermocouple causing the gas valve to cut the pilot and main burner

daren the god, December 2007
link Click here to see other fixes for Glowworm Swiftflow 80.