Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

Potterton Puma 80e - low pressure switch - boiler not firing?

I have just changed a low preesure switch on a Potterton Puma 80e. When I recconnect the two cables the boiler does not fire up. If I leave the cables off the boiler does fire up but then the pressure increases. I have taken the pressure switch off and cleaned inside and made sure there is no blockage before fitting the new pressure switch. I have tried releasing air on pump but no joy.Do not know what else to check as the cables must be connected but then I am left with no DHW or CH!!..please help.
Sunny, November 2007
Just fitted new water pressure switch and had same problem.It came with insulation on wrong terminal. Moved insulation to terminal 3 and connected wires to terminal 1 & 2 (normally closed) Now works fine. Hope that can help

jay, November 2007
how many terminals are there on the switch?

barry, November 2007