GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

pilot won't stay lit on glow worm swift flow 100?

when i release the ignitor button to turn it to the on position the pilot goes out? (right at the last point before i can turn the switch) replaced the thermo coup, pressure is fine, blew/sucked the pressure tubes, even boiled the ignitor jet as recommended by an engineer in HRPC, all with no joy?? anyone got any ideas?????
Darren, May 2005
no probs might pay to get a spare

d.., May 2005
think i found the item you described, was unsure how to check to see if it was faulty though? however, give the two silver connectors a rub with a bit of wire wool and it fired up 1st time! been running now for about 5 hours so may have resolved it, so, Thank you very very much for your help and advise. (oh and my wife thanks you for her 1st HOT shower in 3 days ha ha) thanks once again.

Darren, May 2005
the over heat is connected via 2 wires to the thermocouple either at the gas valve or half way along the t/couple there is an interupter try that

d.., May 2005
thank you. any ideas on what it would/should look like or where it can be found?

Darren, May 2005
you need to check the overheat stat and make sure that is not faulty

d.., May 2005