GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

ariston euro combi boiler?

i get hot water some time when the central heating is on and its very hard to use water.
please let me know what is the problem and how can i sort this out.

shahid
a shahid, January 2008
If you are only getting hot water with the heating on then you need to replace the diverting valve. Or just the DHW diaphragm if the flow switch isnt making.

Lee, March 2008
If you are only getting hot water with the heating on then you need to replace the diverting valve. Or just the DHW diaphragm if the flow switch isnt making.

Lee, March 2008
If you are only getting hot water with the heating on then you need to replace the diverting valve. Or just the DHW diaphragm if the flow switch isnt making.

Lee, March 2008
cheque diafram in diverter valve, first look and see if the centre pin lifts and operates switches when hot tap is operated,

eric, January 2008