Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

how can i fix saunier duval themaclassic f24?

boiler pressure goes to high and comes out pressure relief valve
Joe Hughes, January 2008
I lose pressure when i have the central heating on ie water starts to leak from the overflow pipe then the boiler pressure drops below 1 bar can you tell me what causes this

cihan, May 2012
Sounds like the diaphram on the expansion chamber may have gone. You can tell if there is water at the air valve. I drained a small unused rad and reconnected it without bleeding. The air trapped inside will act as an expansion cushion. You will need a new exp. chamber, but this does not have to be fitted to the boiler. If it is, the boiler has to come off the wall.

John Dickens, October 2010
got the same problem

Liviu, February 2008
Refill expansion tank

bendan, February 2008