Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

how can i fix Vokera mynute 35 HE?

My Vokera boiler mynute 35 He keeps cuts out and has to be re set before it will start up again it then works for a number of hours then cuts out again ??

Code 10 is on the error message can any body explain what the problem is
Howard, February 2008
Check adequate gas supply, fan speeds, CO2 high and low settings, ignition/detection electrodes and finally the condense sensor - pipe may be frozen or just not emptying from trap.

Big A, February 2008
link Click here to see other fixes for Vokera mynute 35 HE.