Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

how can i fix my hotpoint aquarius 900?

I had to turn off the machine at the wall because the door was locked I have reattached the rubber seal but it now just sticks on one thing not going through any cycles
keith wiles, March 2008
Switch power off. Some interlocks prevent the door from opening if the drum is moving. The mechanism that detects this is called a pecker unit and it is located around the motor pulley. It connects to the interlock via a cable assembly. If the pecker unit is broken in the "on" position it may be preventing the interlock opening. Visually check and try to activate the mechanism by hand.
Other interlocks have a secondary locking system which ties in with the pressure switch - the mechanism which detects if there is water present in the drum. If this system is faulty - caused by blockages in the filter, pressure vessel or the thin rubber pipe running to the pressure switch the machine "thinks" its still full of water and wont allow the door to be opened. Take off the top cover, examine the interlock from behind and detach any rubber pipes or cables to try to open it from inside. If all else fails, the interlock itself may be faulty and will have to be broken open. A replacement interlock unit and/or catch will of course be required.
Check out my site for info: www.2ndwave.co.uk/manual.html

dan, March 2008
link Click here to see other fixes for Hotpoint Aquarius.