Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

Ideal ISAR HE30?

It seems that when turning on the Hot Water Taps the boiler fires up and displays 'd' which is correct for the taps but the radiators become really hot and the water from the taps becomes luke warm. sometimes the tap water will go cold but the boiler is still running. Any Ideas?
Martin, April 2008
Yes, your diverter valve is stuck or getting stuck in mid position allowing the hot water called for by the tap to flow into the ch system at the same time.

Valve will need cleaing, or more likely replacing

T, April 2008