Dwayne B. asked ... Intermittent (twice) Then Complete Loss of Power?    |    Aunt Bee asked ... Bernina Update 1630 work light not working?    |    Larry asked ... Hybrid Weed wacker not working with battery?    |    Dan asked ... Why is Google Keep so slow on my iPhone?    |    dave s asked ... Transmission not working?    |    Click here to ask your question

How can i fix my Potterton Puma 80 combination boiler?

When I turn on the hot water tap at the sink, the boiler fires up but shuts off after 5 seconds. It does the same from cold or when central heating is on. System pressure is at about 2 Bar.
Hot water Pressure and flow at sink when tap opened is a bit low. Mains pressure on cold side is good. any ideas?
Peter Butler, May 2008
either the inline filter on the water main into the boiler is blocked (should be cleaned every service interval), you dhw thermister has gone faulty, or the plate to plate heatexchanger has become partially blocked and may need replacing........try the filter first...a common problem

T, May 2008