GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

potterton netaheat 10-16, will not fire up,?

help !, my potterton netaheat 10-16 will not fire up, when switched on by the clock or thermostat, no hot water or heating. you can hear the fan running consantly, but will not fire. the pumps ok and the thermostat is new. A plasterer i am but heating engineer no chance, pass me the hammer !. any help much appreciated. Nigel, the spread.
nigel, May 2008
Check the relay it could have a burned contact

Terry Shears, November 2008
hi i have a 16 22 boiler myself with the same problem and it fires up after a gentle thump to the bottom of the boiler which is where the circuit board is located.i suspect a bad connection on the board and if so re soldering all connections on the board may solve the problem otherwise may be a case of replacing th board.i hope to find out when i try the first option this weekend.i am not corgi registered and this is only my personal experiance but if it is of any help good luck

andy, May 2008
when fan starts do you here the aps switch make (one click when fan starts) would say the problem lies there, either the aps switch is faulty or the flue blocked/partially bocked (check the terminal is not overgrown or something outside) aps tubes spilt, of fan itself not getting to speed and needs replacing

T, May 2008
link Click here to see other fixes for Potterton.