4 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

No burner light (halstead high ace)?

Got a problem with boiler, no burner light, no CH no HW, tried reset tried power off, tried overhear reset.
Danny Owen, June 2008
Most likely your gas valve. There are two coils on this valve. Check resistances of these coils they should read no more than about 10 ohms if your getting open circuit on either coil it's faulty.

Mick, July 2008
Checked flow switches, working fine, sent board back for yet another replacement.

Can't think what else it could be

Daniel Owen, June 2008
Just to add to this, tested so far;

Fan (ok)
Pump (ok)
Thermistors (both reading 13Kohm)
APS (ok)
Flow switches (primary a little flaky but opening and closing)

Gonna be testing flow switches independent of water in a bit but it's doing my head in.

Daniel Owen, June 2008
link Click here to see other fixes for Halstead.