David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

Failing hot water on a Saunier Duval F30E Themaclassic combi?

I have a 4 yr old Saunier F30E standard combi running on natural gas and the hot water is failing dismally. However heating works AOK.

Symptoms-

turn on hot water, boiler fires, flame spreads across whole burner, burns for about 10 seconds, goes out, 15 or so secs later flame re-lights, REPEAT

Items checked so far-

cleaned boiler as per installation manual.

set sensor electrode and ignition electrode gaps to 3.5mm as per manual.

measured voltage at H2 from flame sensor electrode, result 6 volts when flame covering electrode.

disconnected flame sensor, result, lockout with fault code F1 shown on display.

measured voltage across all 3 leads of flow sensor. result 6-7 volts across each terminal.

Checked Control board PCB, no sign of dry joints on soldering. resistors appear to measure OK.

BTW, I am a sparky, and have serviced this boiler regularly plus flushed system and used inhibitor, 18 months ago replaced three way valve actuator and diaphragm, both still working and A1 condition.

Any Saunier experts with ideas of a fix, (don't much fancy paying £150 for new PCB)

TYIA
Shalien, June 2008
Did i just say goog, few to many beers while doing the business.
What I meant to say is Good as ever.

Te-He

Shalien, June 2008
Thanks T!
Stripped the boiler tonight, DHW P to P exchanger was well clogged. used a pack of kettle descaler, good flush thru' works as goog as ever now.
I will be treating it with Fernox system flush tomorrow, then fernox inhibitor, instead of the cheap stuff.
anyone got any objections to that?

all the best

Shalien

Shalien, June 2008
The water does flow hot-cold-hot-cold etc, what is the best way to descale the dhw plate exchanger?

Shalien, June 2008
does the hot water run hot-cold-hot?
assuming so, and the ch works ok, would be looking at
a) cleaning the inline mains water filter
b) descaling or replacing the dhw heat exchanger

T, June 2008