Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Potterton Netaheat Profile 80e?

The boiler will not fire up when heat is called for. The pilot lights up and remains on with the fan working as normal.

I have looked at the fault finding chart and it says " check solenoid GV2, replace if necessary". I take it that this means the Gas Valve. How does one check this?

Another possible option is that the air pressure switch or the tubes to and from it are faulty. How does one check the switch?

Am I on the right track
Walton Boiler, July 2008
if the pilot is alight then the aps and tubes are fine. if the pilot lights and spark stops then it is the gas valve. there are a number of different makes of gas valve for the profile. if the spark continues it is likely to be the pcb.

Kieran, July 2008
gas valve seating stuck replace gas valve

steve bh heating, July 2008
if the pilot is still sparking then it is either a loose ignition electrode or PCB

Steve L @ Glowarm ltd, July 2008