Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

how can I fix leak on combi 105e?

I have a water leak between the diverter manifold and the DHW pressure differential valve,I have replaced the diaphragm in the in the differential valve,what else could be causing the problem?
mike sidaway, July 2008
hi there corgi bloke,did what you said,bought a kit and changed all parts,still got a slight leak, can the water come through from the diverter manifold side,and what maybe the problem?

mike, August 2008
very common leak on this boiler there is a o ring behind the dif pin hexagonal brass nut which always fail and allows water out via the pin if you have changed the dia already its easy enough

corgi bloke, July 2008