Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

help with worcester junior combi boiler please?

my boiler is only four years old but has the last few weeks had an periodical problem with no hot water.when i check the pressure is low/only half bar?can anyone tell me how to top it up?underneath there is a loop with a screwhead both sides.And if i do this will it solve this problem?i believe the pressure should be between one and two??please help its driving me mad!!!!
Hannie, August 2008
The loop you see has a tap on it from mains pressure. Open the tap until the pressure reaches around 2 bar then close it again. If you go above around 3 bar it will vent off to the outside, so about 2 1/2 bar maximum before you turn it off. You may have a very slight leak somewhere that is losing the pressure. There is usually a rust mark or similar where the leak is.

Trev, August 2008