3 hours ago Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Valiant vuw 242/1e dhw fault?

Have a client with above boiler who's dhw would only work when there was a large demand-eg tap belting out. Got the diverter valve service kit and changed all the bits. Have adjustd the microswitch back and forth soo can get the boiler to fire with what ever flow you like, only it cuts out on overheat when the flow drops- filling the bath is ok, but no good for shower. Central heating is appears to be ok.
Steveo, August 2008
It could possibly be the DHW (direct hot water) heat exchanger is getting blocked. That would be my next thing to check.

Robin S, August 2008