Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Worcestor Bosch 24 CDi combi prob?

Just one problem.... boiler turns on heating if boiler is powered up, even though program is set to OFF.
Hot water is fine, shower, taps etc.
Manual troubleshoot guide kind of leads to replacing circuit board, but Im unsure, any advice appreciated and thanks in advance.
Jeff, September 2008
Hi, thanx for reply. 24CDi doesnt have a flow switch, but prob is sorted now, was PCB, cheers.

Jeff, October 2008
Disconnect all external controls, frost stat (if fitted), room stat, internal clock.

Still firing?

Disconnect flow switch (two pink wires).

Still firing?

Yep, pcb.

BunSlinger, September 2008
link Click here to see other fixes for Bosch.