Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

Worcestor Bosch 24 CDi combi prob?

Just one problem.... boiler turns on heating if boiler is powered up, even though program is set to OFF.
Hot water is fine, shower, taps etc.
Manual troubleshoot guide kind of leads to replacing circuit board, but Im unsure, any advice appreciated and thanks in advance.
Jeff, September 2008
Hi, thanx for reply. 24CDi doesnt have a flow switch, but prob is sorted now, was PCB, cheers.

Jeff, October 2008
Disconnect all external controls, frost stat (if fitted), room stat, internal clock.

Still firing?

Disconnect flow switch (two pink wires).

Still firing?

Yep, pcb.

BunSlinger, September 2008
link Click here to see other fixes for Bosch.